CONTACTS
/
ABOUT
About Berry CPG
Careers
Contact Us
News
About Berry Plastics
/
MARKETS
Cathodic Protection
Mining
Offshore Pipelines
Oil & Gas Distribution
Oil & Gas Transmission
Oil & Gas Utility
Pipeline Rehabilitation
Pre-Insulated Pipelines
Refineries
Storage Tanks
Water Distribution
Water Infrastructure
Water Transmission
Wellhead, Gathering & Flow Lines
/
PRODUCTS
Cathodic Protection
AFLX Long Line Linear Anodes
AFLX MMO Anodes
AFLX Polymeric Anodes
Coatings External
Bituminous
Covalence HSP
Polyken
Powercrete
Woven Geotextile Polymeric
Internal Coatings & Linings
Powercrete
Pipe Handling
Rockshield
Repair & Installation Accessory Products
Epoxy Applicaiton & Mixing Tools
Epoxy, PU, & FBE Coating Repair
Filler Materials
Installation Accessories
PE & PP Coating Repair
Repair Accessories
/
APPLICATIONS
Cathodic Protection
Pipeline New Construction Impressed Current Anode
Rehab w/o Excavation
Storage Tank (CP Replacement & Rehab)
Storage Tank (New CP)
Coating Repair
3LPE & 2LPE Repair
3LPP Repair
AE Repair
Cold Applied Tape Coating System Repair
CTE Repair
Epoxy Potable Water Lining Repair
FBE & Epoxy Repair
Hot Applied PE Repair
PU Repair
Coatings: Field Applied Mainline External
Cold Tape Coating Systems
Epoxy Pipeline Coatings
High Temp (>=93°C/200°F)
Coatings: Field Joints, Fittings (External) & Sealing
Bends, Flanges, Fittings & Transitions
Girth Weld (pipe joint)
Girth Weld under in fill
Insulated Pipe Joint
Socket Joints
Weld After Backfill GW Coating (Water)
Coatings: Plant & Mill Applied Mainline (External)
Cold Applied Tape Coating Systems
Epoxy Pipeline Coatings
High Temp (>=93°C/200°F)
Hot Applied Tape Coating Systems
Large Dia O&G
Water Transmission (Lg Dia)
Coatings: Robust Abrasion Resistant
Abrasion Girth Weld Protection for HDD
Abrasion Resistant Mainline for HDD
ARO for FBE
ARO for PE
ARO for PP
Insulated/Pre-Insulated Pipelines
Accessories
Casings
Coatings & Seals
End Caps
Girth Weld (Pipe Joint)
Internal Coatings & Linings
Epoxy Alternative to Cement Mortar Linings
Epoxy Chemical Resistant Linings
Epoxy Flow Efficiency Coatings (O&G )
Epoxy Potable Water Linings
Epoxy Water & Sewage Linings
Pipeline Rehabilitation & Reconditioning
Bell Hole Rehabilitation
Pipe Wall Thickness Repair
Pipelines In-Service (Insitu)
Rehab w/o Excavation
/
LITERATURE
Application Tables
Brochures
Data Sheets
MSDS
Videos
/
REFERENCE
Applications
Contact Us
HOME
>
Applications
> Cathodic Protection
>
Storage Tank (New CP)
>
AnodeFlex 1500-52mA/m (16mA/ft) w/coke
AnodeFlex 1500-52mA/m (16mA/ft) w/coke
Colors:
Adhesives:
Adhesive: Thermoplastic Elastomers & Synthetic Resins
Category:
Cathodic Protection Products
Long-line linear impressed current anode
Central Copper Conductor: #6 AWG, serving as a low resistance busbar to deliver the required current over considerable distance without incurring substantial longitudinal voltage drop.
Conductive polymer: 0.5 inch (13 mm) in diameter special extrusion, sealing the copper conductor from chemical attack, yet allowing current to flow through it, from the conductor to the environment all along its length.
Coke breeze: Pre-packaged, high performance calcined petroleum coke breeze, serving as the active matrix in which the electrochemical reactions take place. Designed for min. 20 years service life at max. current output of 16 mA/ft (52 mA/m).
Fabric jacket: Integrated woven, acid resistant and porous jacket holding the coke breeze in place around the anode.
Protective braid: Tough, porous, non-conductive protective braid enhancing the abrasion and damage resistance of the fabric jacket.
Applications:
AnodeFlex 1500 is a long-line, flexible, cable-like anode.
It is placed in continuous close proximity to the target structure & provides uniform distribution of CP current .
Unique construction allows current to flow long distances down the center conductor, while allowing sufficient cathodic protection current to continuously pass through the conductive polymer all along the length of the anode.
Maintains steel-to-soil "instant-off" potential in the required window of -850mv (-950mv if SRB’s present) and -1200mv.
AnodeFlex 1500's efficiency prevents over-voltage problems such as hydrogen generation and associated rapid coating disbondment.
Interference from other structures and stray currents are virtually eliminated.
AnodeFlex 1500 can often be installed as part of a system rehabiliation on pipelines with decayed coatings
Above ground storage tank bottoms and buried tanks can be more effectively protected from corrosion using this continuous, close proximity anode system.
Features & Benefits:
Pipeline Rehabilitation without Excavation
Easy monitoring of current
A fraction of the cost of recoating
More reliable & economical than discrete anodes
No over- or under-protected areas
Measurably overcomes of variations in soil resistivity
Reference client lay up to 1.25 miles(2 km) per day
Environmentally friendly
Long continuous circuit lengths
Used to rehabilitate operating pipelines
Lower maintenance cost
Fast & less disruptive
Installation with standard cable laying equipment
No loss of revenue & No supply interruptions
Fast, Easy & Cost Effective
Focuses current on the target structure
90% fewer joints compared to other anode systems
Pre-packaging coke breeze
Less vulnerable to splicing errors
Ensures low resistance ground bed all the time
Max Temperature:
85 ºC,
185 ºF
Related Documents:
DS-AFLX-1500-REV7-Feb10
The leading global partner in protecting the integrity of critical infrastructure.